| Panel Busbar Rating |
200 A |
Nameplate busbar continuous rating |
Verified panel label rating |
| Main Service Disconnect |
200 A |
Primary utility service overcurrent device |
Verified utility supply breaker |
| 120% Busbar Overload Limit |
240 A |
NEC 705.12(B)(2)(3)(b) (1.20 × Busbar) |
Permissible aggregate supply ampacity |
| Solar Inverter Nameplate |
800 W |
UL 1741 compliant microinverter (120 V AC) |
Grid-interactive distributed generation |
| Solar Required Backfeed |
8.3 A |
Continuous load factor: 125% of rated current |
Required panel busbar allocation |
| Combined Total Generation + Supply |
208.3 A |
Main Breaker + (Inverter Current × 1.25) |
PASS (<= 120% busbar) |
| Remaining Busbar Headroom |
31.7 A |
(1.20 × Busbar) − Combined Generation Current |
Unencumbered busbar safety margin |
| Branch Circuit Continuous Loading |
PASS (<= 80% limit) |
NEC 210.19(A) 80% rule for continuous branch load |
Conductor thermal overload prevented |